Specification
Mercury 3.5kva Inverter Specification
Voltage Range 180 VAC – 265VAC ± 5 VAC (UPS Mode)
100 VAC – 280 VAC ± 15 VAC (NOR Mode)
Line Low Detection 180V ± 5V (UPS Mode) / 100V ± 15V (NOR Mode)
Line Low Comeback 190V ± 5V (UPS Mode) / 110V ± 10V (NOR Mode)
Line High Detection 265V ± 5V (UPS Mode) / 280V ± 15V (NOR Mode)
Line High Comeback 255V ± 5V (UPS Mode) / 270V ± 10V (NOR Mode)
Frequency Transfer Input Frequency 45-55 Hz
Characteristics (AC)
Inverter Full Load Power 2800
Power Factor 0.8 factor (on resistive load)
On-Line Mode Sine Wave
Battery Mode Sine Wave
On-Line Output voltage Follow the Line Voltage
Battery Mode Output Voltage 200 VAC ± 10%
Transfer Time (No-Load) <15 ms
The frequency at Battery Mode 50 Hz ± 1 Hz
Characteristics (DC)
DC Supply Voltage 48V
Battery Floating Charge Voltage 54.0 VDC ± 0.8 VDC
Charge Current <15 A
Battery Voltage Low Alarm 42.4 VDC ± 0.8 VDC
Battery Discharge Protection 41.6 VDC ± 0.4 VDC
Over Charge Protection > 60.0 VDC ± 0.8 VDC
Reviews
Clear filtersThere are no reviews yet.